Back to Support

Operator guide · v2.0

VECTOR V1 Operator Guide

Shop-floor reference for Metriflux VECTOR V1 on the Height Master integrated tablet — navigation, measurement modes, part programs, calibration, and troubleshooting.

For Operators and setup technicians. This web reference summarizes the VECTOR V1 operator manual shipped with Height Master kits.

What VECTOR V1 does

VECTOR V1 is the shop-floor companion on your Height Master tablet. It displays live Z-axis displacement from the DRO, guides dimensional measurements, runs part programs with pass/fail, applies probe ball compensation, and stores results locally — no cloud required.

LIVE
Live readout, zero/preset, references, and measurement mode launcher
PROG
Part programs — ordered features with nominals, tolerances, and run mode
LOG
Saved measurements, filters, CSV/Excel/PDF export, save program from log
SYS
DRO connection, display, measurement defaults, operators, kiosk

First connection checklist

  1. Mount height gauge and connect USB DRO cable to the tablet
  2. Open VECTOR V1 → LIVE tab
  3. Confirm Link lamp is healthy and readout shows ● LIVE
  4. If probe radius is unknown, run Probe calibration (SYS → Measure or LIVE Probe cal tile)
  5. Optional: linear compensation, max travel cal, and groove/notch capture defaults in SYS

14 measurement modes

Tap a mode tile on LIVE to open a guided flow. Scratch is for setup only — rolling two-point Δ checks that are not saved to history.

Height
Single surface — relative or absolute with probe compensation
ID / OD
Bore and shaft diameter via lower and upper lateral sweeps (ProbeSense AutoReverse)
Concentricity
Inner vs outer wall eccentricity at one axial station
Distance
Point-to-point live capture, or derive ΔZ from two logged features
Groove / Notch
Internal slot width or external lug width — point capture or sweep per wall
Flatness / Perp. / Runout
Surface TIR, squareness between faces, or rotation TIR over one revolution
Steps / Taper / 2D Bore
Chain height increments, wedge-block angle, or multi-hole 2D map with rotation pass
Scratch
Rolling Δ for setup — not written to LOG

Part programs (PROG)

Define a reusable inspection sequence for a part number, then run it step-by-step with automatic pass/fail against drawing limits.

  1. PROG → enter Name and optional Drawing # → Create
  2. Add features: label, mode, nominal, ± tolerances (or max TIR for flatness/runout)
  3. Tap Run → optional serial/lot # → step-through wizard guides each feature
  4. On complete: summary, PDF run report, or run again with a new serial

Create programs from scratch in PROG, or select ad-hoc LOG rows in measurement order → Save program.

Auto-capture & stability gate

When the stability gate is enabled (recommended), Z must stay within ±0.01 mm for 400 ms before Capture works. Lamps cycle MOVING → SETTLING → SETTLED.

Stability gate
Toggle on LIVE Stability tile (long-press) or SYS → Display
Auto-capture
Teach a profile from a gauge-block approach — arms automatic contact capture
Inspection presets
Per-mode saved limit sets with nominal and ± tolerance bands for pass/fail

Calibration wizards

Run on a clean granite plate with certified masters. Allow temperature stabilization.

Probe calibration
Ring gauge, step gauge, or gauge block — sets ball radius for compensation
Linear compensation
Corrects Z scale error (displayed = scale × raw + offset)
Wedge calibration
Sets horizontal span for taper / angle measurements
Max travel cal
Full-scale Z range for bar gauge and measurement visuals (50–3000 mm)

Recalibrate probe after replacement, visible wear, or out-of-family ID/OD readings.

LOG history & export

The LOG tab stores ad-hoc measurements and program runs locally on the tablet. Select rows with checkboxes to export.

CSV
SPC export with timestamp, mode, value, pass flag, tolerances, and diagnostics
Excel
Spreadsheet export for shop-floor analysis and QMS integration
PDF
Branded inspection report — configure company name, tagline, and logo in SYS → Admin → Reports

Quick troubleshooting

DISCONNECTED
Reseat USB cable; tap STOP then LINK on LIVE
Hold steady until SETTLED
Wait for SETTLED lamp; reduce bench vibration
ID too small / OD too large
Recalibrate probe ball radius
AUTOCAP BLOCK
Enable stability gate before using auto-capture
Export buttons disabled
Select at least one row with the checkbox in LOG

Operator FAQ

Common questions from the VECTOR V1 operator manual.

No. ZERO and PRESET change datum offset only — linear scale compensation is separate.